Product Overview
A high-tensile heat-treated steel wire is enclosed in a rigid cylindrical stainless-steel sensor assembly and connected to a sensitive diaphragm. Fluid pressure changes diaphragm deflection and wire tension. A central magnetic coil excites the wire; frequency is converted to pressure by a compatible readout. The sensor is isolated from external body stresses, and O-ring sealing protects against moisture and corrosion.
Key Features
- High accuracy, repeatability and long-term stability
- Sealed stainless-steel construction
- Temperature compensation and integral thermistor
- Resistance to electrical noise and long-distance signal transmission
- Low maintenance
- Compatible with remote automatic logging
- Optional lightning protection; surge arrestor described for standard models
- Low air entry or high air entry filter options as applicable
Applications
- Groundwater levels and pore water pressure
- Boreholes, wells, dams and embankments
- Slope stability and landslides
- Tunnels and underground construction
- Retaining walls and deep excavation
- Foundations and pile load monitoring
- Soil consolidation and mining investigations
- Bridges and infrastructure
- Concrete and hydraulic projects
- Pipelines and reservoirs
- Structural health monitoring
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | Data Digger Equipment |
| Series | DDE 2000 |
| Models | DDE-2001 / DDE-2002 / DDE-2003 / DDE-2004 / DDE-2005 |
| Sensor | Vibrating wire pressure transducer |
| Standard transducer material | 316 grade stainless steel |
| General pressure range (standard family description) | -70 kPa to 20 MPa |
| DDE-2001 type | Standard piezometer |
| DDE-2001 standard range | 2 / 5 / 7 / 10 kg/cm² |
| DDE-2001 pressure range | 200 / 500 / 700 kPa; 1 / 2 / 3 MPa |
| DDE-2001 dimensions | 180 × 20 mm or 200 × 20 mm (L × diameter) |
| DDE-2002 type | Small diameter piezometer |
| DDE-2002 standard range | 2 / 5 kg/cm² |
| DDE-2002 pressure range | 200 / 500 kPa |
| DDE-2002 dimensions | 165 × 20 mm (L × diameter) |
| DDE-2003 type | Drive point piezometer |
| DDE-2003 standard range | 2 / 5 / 7 / 10 kg/cm² |
| DDE-2003 pressure range | 200 / 500 / 700 kPa; 1 / 2 / 3 / 5 / 7.5 MPa |
| DDE-2003 dimensions | 200 × 28 mm (L × diameter) |
| Overrange (2001–2003) | 2 × rated pressure |
| Resolution (2001) | 0.1% F.S. |
| Resolution (2002–2003) | 0.1% F.S. (minimum as stated) |
| Accuracy (2001–2003) | ±0.5% F.S. |
| Linearity (2001–2003) | <0.5% F.S. |
| Operating temperature (2001–2003) | -20°C to +60°C |
| DDE-2004 type | Threaded adapter for hydraulic pressure line |
| DDE-2005 type | Heavy-duty piezometer |
| Standard filter options | Low air entry sintered stainless steel / high air entry ceramic |
| Temperature monitoring | Integral thermistor |
| Standpipe material | Rigid PVC |
| Standpipe outside diameter | 12–25.4 mm |
| Standpipe maximum wall thickness | 1.5 mm |
Standard Models DDE-2001 / DDE-2002 / DDE-2003
Designed for pore water pressure in partially or fully saturated soil. The general description specifies 316 stainless steel, integrated over-voltage surge arrestor, filter choice and integral thermistor. Model-specific pressure ranges are listed in the specifications above.
DDE-2004 Threaded Adapter
A threaded connection enables direct monitoring of hydraulic pressure lines, including dam uplift pressure and hydraulic structures.
DDE-2005 Heavy Duty
A rigid housing with sealed cable entry and removable high or low air entry filter keeps solids away from the sensing diaphragm. Suitable for soil, earth and rock fill, concrete, boreholes and small-diameter pipes. Filter removal allows calibration, cleaning and saturation.
Data Acquisition
A vibrating wire readout displays frequency and calculated pressure in engineering units. Automatic loggers and software provide interval-based acquisition, trend analysis, custom displays and threshold alerts. The thermistor enables temperature correction.
Standpipe
Rigid corrosion-resistant PVC tubing is supplied in lengths suited to installation. Larger diameter tubing may be selected for water level sounders or other probes.
Configuration Notes
The brochure does not provide separate numerical specifications for DDE-2004 or DDE-2005. The broad standard-family pressure range is distinct from the individual model tables; confirm selected model, range, filter and dimensions.
Manufacturer Information
Data Digger Equipment • 568 K/62-A Krishnapalli, Alambagh, Lucknow, Uttar Pradesh 226005, India
GST: 09AFEPB9198K1ZW
Website: www.datadigger.co.in
Email: info@datadigger.co.in
Contact: +91-7880650032 / +91-7505751181
The manufacturer brochure identifies the organization as ISO 9001:2015 certified (certificate no. 304920053008Q). Confirm the required configuration with the manufacturer before ordering.

