Total Pressure Cell – DDE-1101 / DDE-1102

Vibrating wire total pressure cells for soil/contact pressure and shotcrete lining stress, available in circular earth and rectangular shotcrete configurations.

Get a Quote Add to wishlist

Product Overview

The DDE-1100 series uses stainless-steel pressure plates enclosing a sealed de-aired fluid cavity. Applied pressure is transferred through the fluid to a vibrating wire pressure transducer. Frequency changes are converted to engineering pressure readings for static and changing loads.

Key Features

  • Stable vibrating wire measurement
  • Corrosion-resistant stainless steel
  • Long-term field monitoring
  • Temperature measurement/compensation capability
  • Portable readout and automatic logger compatibility
  • Optional lightning protection

Applications

  • Soils and embankments
  • Retaining wall contact pressure
  • Tunnel lining stresses
  • Bridge abutments
  • Concrete stress
  • Dams and underground structures
  • Soil consolidation and foundations

Technical Specifications

Parameter Specification
Manufacturer Data Digger Equipment
Series DDE-1100
Models DDE-1101 Earth Pressure Cell / DDE-1102 Shotcrete Pressure Cell
Sensor type Vibrating Wire Pressure Cell
Pressure ranges (both models) 2 / 3 / 5 / 7 / 10 / 20 / 35 MPa (as required)
Accuracy (both) ±0.5% F.S.
Resolution (both) 0.1% F.S.
Linearity (both) <0.5% F.S.
Operating temperature (both) -20°C to +60°C
DDE-1101 dimensions 6 × 200 mm (length × diameter as labelled)
DDE-1102 dimensions 250 × 150 × 6 mm (L × B × H)
DDE-1101 construction Two circular stainless-steel plates; de-aired oil cavity
DDE-1102 construction Stainless-steel pressure plates; de-aired fluid cavity
Temperature monitoring Integrated thermistor described; option to confirm
Signal Frequency output

DDE-1101 Earth Pressure Cell

Circular welded plates transmit earth or structural contact pressure through de-aired oil to the transducer.

DDE-1102 Shotcrete Pressure Cell

Designed to monitor radial and tangential stress in sprayed concrete tunnel linings and ground-support interaction during and after construction.

Operation and Data Acquisition

Electromagnetic excitation produces wire resonance. A readout measures frequency and converts it to pressure. Automatic loggers and monitoring software can collect readings at programmed intervals, display trends and configure threshold alerts.

Available Accessories

  • Special protective coating for saline or corrosive environments
  • Waterproof cable splicing kit
  • Junction box for multiple cables
  • Portable vibrating wire readout
  • Optional automatic data logger
  • Optional lightning protection

Configuration Notes

Pressure ranges and dimensions are reproduced as specified in the brochure. Temperature measurement is described as an option in features and as integrated in operation; confirm the required configuration.

Manufacturer Information

Data Digger Equipment • 568 K/62-A Krishnapalli, Alambagh, Lucknow, Uttar Pradesh 226005, India

GST: 09AFEPB9198K1ZW

Website: www.datadigger.co.in
Email: info@datadigger.co.in
Contact: +91-7880650032 / +91-7505751181

The manufacturer brochure identifies the organization as ISO 9001:2015 certified (certificate no. 304920053008Q). Confirm the required configuration with the manufacturer before ordering.

Manufacturer

Data Digger Equipment

Series

DDE-1100

Models

DDE-1101 Earth Pressure Cell / DDE-1102 Shotcrete Pressure Cell

Sensor type

Vibrating Wire Pressure Cell

Pressure ranges (both models)

2 / 3 / 5 / 7 / 10 / 20 / 35 MPa (as required)

Accuracy (both)

±0.5% F.S.

Resolution (both)

0.1% F.S.

Linearity (both)

<0.5% F.S.

Operating temperature (both)

-20°C to +60°C

DDE-1101 dimensions

6 × 200 mm (length × diameter as labelled)

DDE-1102 dimensions

250 × 150 × 6 mm (L × B × H)

DDE-1101 construction

Two circular stainless-steel plates; de-aired oil cavity

DDE-1102 construction

Stainless-steel pressure plates; de-aired fluid cavity

Temperature monitoring

Integrated thermistor described; option to confirm

Signal

Frequency output