Vibrating Wire Piezometer – DDE 2000 Series

Sealed vibrating wire piezometer family for pore water pressure and groundwater monitoring, with standard, small diameter, drive point, threaded and heavy-duty models.

Get a Quote View wishlist

Product Overview

A high-tensile heat-treated steel wire is enclosed in a rigid cylindrical stainless-steel sensor assembly and connected to a sensitive diaphragm. Fluid pressure changes diaphragm deflection and wire tension. A central magnetic coil excites the wire; frequency is converted to pressure by a compatible readout. The sensor is isolated from external body stresses, and O-ring sealing protects against moisture and corrosion.

Key Features

  • High accuracy, repeatability and long-term stability
  • Sealed stainless-steel construction
  • Temperature compensation and integral thermistor
  • Resistance to electrical noise and long-distance signal transmission
  • Low maintenance
  • Compatible with remote automatic logging
  • Optional lightning protection; surge arrestor described for standard models
  • Low air entry or high air entry filter options as applicable

Applications

  • Groundwater levels and pore water pressure
  • Boreholes, wells, dams and embankments
  • Slope stability and landslides
  • Tunnels and underground construction
  • Retaining walls and deep excavation
  • Foundations and pile load monitoring
  • Soil consolidation and mining investigations
  • Bridges and infrastructure
  • Concrete and hydraulic projects
  • Pipelines and reservoirs
  • Structural health monitoring

Technical Specifications

Parameter Specification
Manufacturer Data Digger Equipment
Series DDE 2000
Models DDE-2001 / DDE-2002 / DDE-2003 / DDE-2004 / DDE-2005
Sensor Vibrating wire pressure transducer
Standard transducer material 316 grade stainless steel
General pressure range (standard family description) -70 kPa to 20 MPa
DDE-2001 type Standard piezometer
DDE-2001 standard range 2 / 5 / 7 / 10 kg/cm²
DDE-2001 pressure range 200 / 500 / 700 kPa; 1 / 2 / 3 MPa
DDE-2001 dimensions 180 × 20 mm or 200 × 20 mm (L × diameter)
DDE-2002 type Small diameter piezometer
DDE-2002 standard range 2 / 5 kg/cm²
DDE-2002 pressure range 200 / 500 kPa
DDE-2002 dimensions 165 × 20 mm (L × diameter)
DDE-2003 type Drive point piezometer
DDE-2003 standard range 2 / 5 / 7 / 10 kg/cm²
DDE-2003 pressure range 200 / 500 / 700 kPa; 1 / 2 / 3 / 5 / 7.5 MPa
DDE-2003 dimensions 200 × 28 mm (L × diameter)
Overrange (2001–2003) 2 × rated pressure
Resolution (2001) 0.1% F.S.
Resolution (2002–2003) 0.1% F.S. (minimum as stated)
Accuracy (2001–2003) ±0.5% F.S.
Linearity (2001–2003) <0.5% F.S.
Operating temperature (2001–2003) -20°C to +60°C
DDE-2004 type Threaded adapter for hydraulic pressure line
DDE-2005 type Heavy-duty piezometer
Standard filter options Low air entry sintered stainless steel / high air entry ceramic
Temperature monitoring Integral thermistor
Standpipe material Rigid PVC
Standpipe outside diameter 12–25.4 mm
Standpipe maximum wall thickness 1.5 mm

Standard Models DDE-2001 / DDE-2002 / DDE-2003

Designed for pore water pressure in partially or fully saturated soil. The general description specifies 316 stainless steel, integrated over-voltage surge arrestor, filter choice and integral thermistor. Model-specific pressure ranges are listed in the specifications above.

DDE-2004 Threaded Adapter

A threaded connection enables direct monitoring of hydraulic pressure lines, including dam uplift pressure and hydraulic structures.

DDE-2005 Heavy Duty

A rigid housing with sealed cable entry and removable high or low air entry filter keeps solids away from the sensing diaphragm. Suitable for soil, earth and rock fill, concrete, boreholes and small-diameter pipes. Filter removal allows calibration, cleaning and saturation.

Data Acquisition

A vibrating wire readout displays frequency and calculated pressure in engineering units. Automatic loggers and software provide interval-based acquisition, trend analysis, custom displays and threshold alerts. The thermistor enables temperature correction.

Standpipe

Rigid corrosion-resistant PVC tubing is supplied in lengths suited to installation. Larger diameter tubing may be selected for water level sounders or other probes.

Configuration Notes

The brochure does not provide separate numerical specifications for DDE-2004 or DDE-2005. The broad standard-family pressure range is distinct from the individual model tables; confirm selected model, range, filter and dimensions.

Manufacturer Information

Data Digger Equipment • 568 K/62-A Krishnapalli, Alambagh, Lucknow, Uttar Pradesh 226005, India

GST: 09AFEPB9198K1ZW

Website: www.datadigger.co.in
Email: info@datadigger.co.in
Contact: +91-7880650032 / +91-7505751181

The manufacturer brochure identifies the organization as ISO 9001:2015 certified (certificate no. 304920053008Q). Confirm the required configuration with the manufacturer before ordering.

Manufacturer

Data Digger Equipment

Series

DDE 2000

Models

DDE-2001 / DDE-2002 / DDE-2003 / DDE-2004 / DDE-2005

Sensor

Vibrating wire pressure transducer

Standard transducer material

316 grade stainless steel

General pressure range (standard family description)

-70 kPa to 20 MPa

DDE-2001 type

Standard piezometer

DDE-2001 standard range

2 / 5 / 7 / 10 kg/cm²

DDE-2001 pressure range

200 / 500 / 700 kPa; 1 / 2 / 3 MPa

DDE-2001 dimensions

180 × 20 mm or 200 × 20 mm (L × diameter)

DDE-2002 type

Small diameter piezometer

DDE-2002 standard range

2 / 5 kg/cm²

DDE-2002 pressure range

200 / 500 kPa

DDE-2002 dimensions

165 × 20 mm (L × diameter)

DDE-2003 type

Drive point piezometer

DDE-2003 standard range

2 / 5 / 7 / 10 kg/cm²

DDE-2003 pressure range

200 / 500 / 700 kPa; 1 / 2 / 3 / 5 / 7.5 MPa

DDE-2003 dimensions

200 × 28 mm (L × diameter)

Overrange (2001–2003)

2 × rated pressure

Resolution (2001)

0.1% F.S.

Resolution (2002–2003)

0.1% F.S. (minimum as stated)

Accuracy (2001–2003)

±0.5% F.S.

Linearity (2001–2003)

<0.5% F.S.

Operating temperature (2001–2003)

-20°C to +60°C

DDE-2004 type

Threaded adapter for hydraulic pressure line

DDE-2005 type

Heavy-duty piezometer

Standard filter options

Low air entry sintered stainless steel / high air entry ceramic

Temperature monitoring

Integral thermistor

Standpipe material

Rigid PVC

Standpipe outside diameter

12–25.4 mm

Standpipe maximum wall thickness

1.5 mm