3D In-Place Inclinometer with Settlement (X-Y-Z) – DDE-502 IPIS

The DDE-502 IPIS from Data Digger Equipment is a configurable in-place 3D inclinometer system for measuring subsurface lateral movement (X–Y) and settlement or heave (Z) within one borehole. It combines biaxial MEMS tilt sensing with contactless magnetic displacement measurement and supports automated data acquisition.

  • X–Y range: ±30°; Z displacement range: 100 mm
  • Specified accuracy: ±0.1% FS
  • Digital SDI-12 sensor chain; up to 61 sensors per datalogger channel
  • Suitable for tunnels, excavations, foundations, dams and other geotechnical monitoring projects
  • Project-specific configuration; contact Data Digger Equipment for a quotation.

Get a Quote Add to wishlist

Product overview

The DDE-502 IPIS combines horizontal deformation and vertical displacement monitoring in a single inclinometer casing. Successive readings help engineers evaluate changes in ground movement, identify deformation patterns and assess construction control measures over time. Automated monitoring and configured alarms can support early warning, but do not replace engineering assessment.

Key features

  • Three-axis borehole profiling with combined IPIS probes
  • Flexible IPIS, IPI-only and settlement-only configurations at selected depths
  • Reusable probes that can be removed and reconfigured for another installation
  • Temperature-stable sensing and straightforward digital data acquisition
  • Compact datalogger with configuration software
  • Single three-conductor bus in a daisy chain; no multiplexer required for the described arrangement

Applications

  • Deep foundations and deep excavations
  • Tunnels and monitoring of adjacent construction activity
  • Dam abutments
  • Ports, airports and bridges
  • Landslide zones and slope movement monitoring
  • Construction control, stability investigations and post-construction ground monitoring

Sensor configurations

Parameter Specification
IPIS Combined X–Y lateral movement and Z settlement/heave
IPI X–Y lateral movement only
Settlement sensor Z displacement only
Mixed sensor chain IPIS, IPI and settlement sensors at different levels in the same borehole

In a tunnel project, combined sensors may cover the tunnel excavation zone while settlement-only sensors monitor levels above and below it. In deep excavations, the IPIS chain can span the excavation depth.

System construction and measurement principle

ABS inclinometer tubes are joined by fixed or telescopic couplings. Special spider magnet rings are positioned at selected depths outside the casing. Inside the grooved casing, the probe chain uses sprung wheel assemblies and adjustable gage tubes to establish measurement segments. A waterproof stainless-steel magnetic sensor body monitors relative vertical displacement, while the biaxial MEMS sensor records inclination.

During setup, a magnetic probe locates the rings, and the settlement sensors are positioned using the available gage tube adjustments. Ground movement changes casing inclination; settlement or heave changes the relative location of each magnetic ring. Comparison against initial readings allows displacement profiles to be evaluated. A known fixed reference is necessary for reconstructing the full profile; vertical readings may be referenced to the borehole top or a fixed bottom datum magnet.

The brochure recommends surveying initial casing-top coordinates and elevation and recording baseline readings with a manual digital inclinometer and magnetic probe for later comparison.

Technical specifications – probe

Parameter Specification
Sensor technology Biaxial MEMS (X–Y); contactless magnetic sensor (Z)
Measurement range ±30° (X–Y); 100 mm (Z)
Accuracy ±0.1% FS (as specified; brochure footnote 1 is not defined)
Temperature range −20°C to +80°C
Output Serial output; SDI-12 digital bus
Communication speed 1200 bits/sec
Length L (metric; brochure lists m) 30, 50, 100, 150, 200, 300; resolution 1 mm
Length L (imperial; brochure lists ft) 50, 100, 150, 300, 500; resolution 0.01 in
Settlement sensor coarse adjustment 25 mm / 50 mm / 75 mm
Settlement sensor fine adjustment 50 mm total (±25 mm)

Length L options and units are reproduced as listed in the datasheet; confirm their interpretation and the conditions of the accuracy specification before ordering.

Technical specifications – datalogger

Parameter Specification
Datalogger DDEDL; DDEDL-01 referenced for telemetry
Channels 1
Sensors per channel 61
Memory 64-Mbit flash; 2 million data points
Measurement interval 5 seconds to 168 hours (linear mode)
Data export CSV text file
Communication port RS-232 (standard), 115 kbps
Temperature measurement −20°C to +70°C; 0.1°C resolution
Operating temperature −30°C to +70°C
Humidity 100% (as specified)
Power supply 2 × D-size 3.6 V / 19 Ah lithium cells; or 2 × D-size 1.5 V high-power alkaline cells; or 12 V SMF battery rechargeable from AC mains or solar panel
Housing Corrosion-resistant, weatherproof enclosure
Antenna (telemetry option) Built-in or separately mounted
Remote transmission GSM/GPRS modem, subject to network coverage; user-provided data SIM
Local retrieval Direct download to laptop or PC

Data acquisition and transmission

The SDI-12 digital chain carries readings from multiple sensors on one bus cable. The DDEDL datalogger stores observations with date, time and battery voltage in non-volatile memory. More frequent measurement consumes battery power faster. Field data can be downloaded directly to a computer, or transferred remotely through GSM/GPRS where service is available. The telemetry option requires a data SIM for each logger.

Drishti web-based data management

The optional cloud-hosted Drishti platform supports browser-based access to project data, charts, reports and configured alarms. Multiple authorized users can review data from different locations using computers, tablets or smartphones. The brochure describes this service as a rental subscription with an initial setup fee and ongoing monthly charges; it is not assumed to be included with the instrument.

System components and accessories

  • IPIS probe assembly with biaxial MEMS and magnetic settlement sensors
  • IPI-only and settlement-only sensors, depending on configuration
  • ABS inclinometer casing and fixed/telescopic couplings
  • Special spider magnets and datum magnet
  • Adjustable gage tubes, couplers, wheel assemblies, swivel assembly and universal joint
  • Placement tubing, suspension kit, protection cap and extension shaft
  • Three-core SDI-12 bus cable, waterproof connectors and junction box
  • Magnetic probe for initial ring positioning
  • DDEDL datalogger and optional GSM/GPRS telemetry equipment

These are system components illustrated or described in the brochure, not a confirmed standard package. Final quantities and scope of supply depend on the project.

Ordering information

  • Application and borehole depth(s)
  • Required number of IPIS and IPI sensors in each borehole
  • Gage length and placement tubing length
  • Drawing of any borehole section requiring settlement-only measurement
  • Preferred data transmission option

Request a project-specific quotation and confirm sensor configuration, accessories, installation requirements and cloud service scope before ordering.

Manufacturer information

Data Digger Equipment
568 K/62-A Krishnapalli, Alambagh, Lucknow, Uttar Pradesh 226005, India
Website: www.datadigger.co.in
Email: info@datadigger.co.in
Phone: +91-7880650032 / +91-7505751181
GSTIN: 09AFEPB9198K1ZW

The supplied brochure identifies the organization as ISO 9001:2015 certified. Current certification status has not been independently verified.

Brand

Data Digger Equipment

Model

DDE-502 IPIS

Monitoring axes

X–Y lateral movement and Z settlement/heave

Sensor technology

Biaxial MEMS (X–Y); contactless magnetic sensor (Z)

X–Y measuring range

±30°

Z measuring range

100 mm

Accuracy

±0.1% FS (as specified)

Probe temperature range

−20°C to +80°C

Digital interface

SDI-12

Output

Serial output

Data rate

1200 bits/sec

Gage tube adjustment

Coarse: 25/50/75 mm; fine: ±25 mm

Datalogger

DDEDL

Channels

1

Sensors per channel

61

Memory

64-Mbit flash; 2 million data points

Measurement interval

5 seconds to 168 hours

Data export

CSV

Communication port

RS-232; 115 kbps

Datalogger operating temperature

−30°C to +70°C

Datalogger temperature measurement

−20°C to +70°C; 0.1°C resolution

Humidity

100% (as specified)

Power options

D-size lithium or alkaline cells / 12 V SMF battery

Telemetry

Optional GSM/GPRS

Cloud platform

Drishti (rental service)

Casing

ABS inclinometer access tubing